Interlink-electronics FSR 400 Series Manual de usuario Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 37
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
www.interlinkelectronics.com
19
FSR
®
Integration Guide
Environmental Performance Specifications
PARAMETER TYPICAL R CHANGE
NOTES
Hot Operation
-15% 85°C after 1 hour
Cold Operation
-5% -40ºC after 1 hour soak
Hot Humid Operation
+10% +85°C, 95% RH, after 1hour
Hot or Cold Storage
-10% -25ºC to +85°C, 120hrs
Hot Humid Storage Temperature
+ 30% of established nominal
resistance
+85°C, 95% RH, 240 hours
Thermal Shock
± 2% typical
-25ºC to +70°C, 10 Cycles,
15 minute dwell,
5 minute transitions
Note: Specifications are derived from measurements taken at 1000 grams.
Durability Performance Specifications
PARAMETER TYPICAL R CHANGE
NOTES
Tap Testing
-10% 10 million actuations, 1kg, 4Hz
Constant Load
-5% 2.5 kg standing load, 24 hrs
Chemical Resistance
The following chemicals do not affect the operation when applied
to the outside of the sensor: cola, coffee, isopropyl alcohol, soap
solution, household cleaners. No others tested. Application is a
single drop on the exterior of the sensor that is allowed to soak
until evaporation and does not enter the sensor.
Sensitivity to Noise/Vibration
No effect
Note: Specification derived from measurements taken at 1000 grams.
Vista de pagina 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 36 37

Comentarios a estos manuales

Sin comentarios